Ngày đăng: 18/12/2017
Hollow fiber (HF) and flat sheet (FS) Sponge MBRs were operated at 10–20 LMH flux treating hospital wastewater. Simultaneous nitrification denitrification (SND) occurred considerably with TN removal rate of 0.011–0.020 mg TN mg VSS−1 d−1. Furthermore, there was a remarkable removal of antibiotics in both Sponge MBRs, namely Norfloxacin (93–99% (FS); 62–86% (HF)), Ofloxacin (73–93% (FS); 68–93% (HF)), Ciprofloxacin (76–93% (FS); 54–70% (HF)), Tetracycline (approximately 100% for both FS and HF) and Trimethoprim (60–97% (FS); 47–93% (HF). Whereas there was a quite high removal efficiency of Erythromycin in Sponge MBRs, with 67–78% (FS) and 22–48% (HF). Moreover, a slightly higher removal of antibiotics in FS than in HF achieved, with the removal rate being of 0.67–32.40 and 0.44–30.42 µg mg VSS−1 d−1, respectively. In addition, a significant reduction of membrane fouling of 2–50 times was achieved in HF-Sponge MBR for the flux range.
Hospital wastewater
Antibiotic
Sponge membrane bioreactor
Hollow fiber (HF)
Flat sheet (FS)